Transformer: Input leads are 20 AWG. Output leads are 14 AWG. Lead insulation is 105 °C. The transformer uses a class B 130 °C insulation system.
Enclosure: Enclosure temperature will not exceed 70 °C @ 40 °C ambient. Wiring compartment has 2 knockouts sized for 3/4 inch screw cable connectors. The removable cover for the wiring compartment is secured in place by a screw. The enclosure is black powder coated.
General
- Manual reset thermal circuit breaker on the secondary side.
- Controlled with a low-voltage dimmer.
- ETL listed CSA listed
- UL standard 5085-1
- NEMA 3R enclosure
- Maximum Load 150W
- Input Voltage 120 V 60 Hz
- Output Voltage Full Load 11.5 VDC
- Input Current Full Load 1240 mA
- Open Circuit Volts 12.5 VDC
- Output Current Full Load 4.8 A
- Efficiency 89.20% Coil Former
Weight | 8 lbs |
---|